ADC 8.1 Build 7: New Features
[ top ]
ADC 8.1 Build 7: Fixes
ADC 8.1 Build 7: Fixes — AdBeam
-
Minimum number of tension bars output for the solution reinforcement is incorrect.
[NCR1636] (Fixed 03 July 2007; released in AdBeam.dll 8.1.7.4 with ADC 8.1 Build 7 Release 4)
-
ADC crashes when pasting the records in the user load cases table.
[NCR1884] (Fixed 16 August 2007; released in Adc.exe 8.1.7.4 with ADC 8.1 Build 7 Release 4)
-
Many Adbeam warning messages are referring to BS8110 clauses for Hong Kong code of practice.
[NCR12386] (Fixed 07 January 2008; released in AdBeam.dll 8.1.7.4 with ADC 8.1 Build 7 Release 4)
-
Minimum area of comression rebar output is incorrect for a cantilever span.
[NCR2387] (Fixed 07 January 2008; released in AdBeam.dll 8.1.7.4 with ADC 8.1 Build 7 Release 4)
-
Minimum area of tension reinforcement output is incorrect for the flanged beam when neutral axis lies inside the flange.
[NCR2563] (Fixed 05 March 2008; released in AdBeam.dll 8.1.7.4 with ADC 8.1 Build 7 Release 4)
[ top ]
ADC 8.1 Build 4: New Features
[ top ]
ADC 8.1 Build 4: Fixes
ADC 8.1 Build 4: Fixes — AdBeam
-
ADC may propose a design that has a spacing between longitudinal bars that is less than
the user-specified minimum.
[NCR1344] (Fixed 24 May 2007; released in AdBeam.dll 8.1.4.0 with ADC 8.1 Build 4 Release 1)
-
The use of links for slab design is misleading as these are not offered in the final solution.
[NCR1345] (Fixed 28 May 2007; released in Adc.exe 8.1.4.0 with ADC 8.1 Build 4 Release 1)
-
AdBeam's Redistribution table should be clearer that % values must be entered as e.g. "15%"
rather than "15". If the latter is entered then AdBeam assumes that this is e.g. 15kNm.
[NCR1346] (Fixed 28 May 2007; released in AdBeam.dll 8.1.4.0 with ADC 8.1 Build 4 Release 1)
-
The clause for limitation on depth of neutral axis in HKCP 04 is not being considered.
[NCR1529] (Fixed 31 May 2007; released in AdBeam.dll 8.1.4.0 with ADC 8.1 Build 4 Release 1)
-
ADC 8.1 Build 4 installation rebuilt to address installation issues. (No change to
functionality of ADC.)
(Released 5 Mar 2008 in ADC 8.1 Build 4 Release 2)
[ top ]
ADC 8.1 Build 3: New Features
[ top ]
ADC 8.1 Build 3: Fixes
ADC 8.1 Build 3: Fixes — AdBeam
-
The graphic view may fail to show all the longitudinal bars that are recommended by the design. The textual output view details the correct number of bars.
[NCR28] (Fixed 9 February 2007; released in AdBeam.dll 8.1.3.0 with ADC 8.1 Build 3 Release 1)
-
ADC may represent load diagrams incorrectly.
[NCR30] (Fixed 9 February 2007; released in Adc.exe 8.1.3.0 with ADC 8.1 Build 3 Release 1)
-
AdBeam allows cantilever moments to be redistributed.
[NCR61] (Fixed 14 February 2007; released in AdBeam.dll 8.1.3.0 with ADC 8.1 Build 3 Release 1)
-
AdBeam fails to give warning if the tension steel exceeds the maximum allowable reinforcement.
[NCR62] (Fixed 01 November 2006; released in AdBeam.dll 8.1.3.0 with ADC 8.1 Build 3 Release 1)
[ top ]
ADC 8.1 Build 3: Fixes — AdCol
-
The Mxx/Myy chart option should be disabled when the design option is set to uni-axial.
[NCR22] (Fixed 6 February 2007; released in Adc.exe 8.1.3.0 with ADC 8.1 Build 3 Release 1)
-
AdCol may allow bar arrangements with spacing greater than the RDM limit of 300 mm.
[NCR59] (Fixed 12 December 2006; released in AdcData.dll 30.17.0.0 with ADC 8.1 Build 3 Release 1)
-
Check for maximum spacing in tension for RDM and BS8110 may give inconsistent results.
[NCR60] (Fixed 2 November 2006; released in AdCol.dll 8.1.3.0 with ADC 8.1 Build 3 Release 1)
-
If design results are available, plotting N/M chart may result in a discontinuity in the curve.
[NCR63] (Fixed 10 February 2007; released in Adc.exe 8.1.3.0 with ADC 8.1 Build 3 Release 1)
-
AdCol may fail to save all the load cases.
[NCR64] (Fixed 6 February 2007; released in Adc.exe 8.1.3.0 with ADC 8.1 Build 3 Release 1)
[ top ]
ADC 8.1 Build 1: New Features
ADC 8.1 Build 1: New Features — General
-
Concrete design implemented / rationalised for the following design codes:
- BS8110-1: 1985
|
|
- resurrected |
- BS8110-1: 1997 (2005)
|
|
- 2005 amendment added |
- Hong Kong Code of Practice 1987
|
|
- corrected |
- Hong Kong Code of Practice 2004
|
|
- added |
-
A dockable gateway has been implemented. This allows views to be maximised beside the gateway, rather than over it.
ADC 8.1 Build 1: New Features — AdBeam
-
The warning given regarding cover being inadequate has been clarified to explain that the cover is inadequate based on the largest bar size that has been selected.
-
The option to include self weight has been set to true by default, rather than false.
[ top ]
ADC 8.1 Build 1: Fixes
ADC 8.1 Build 1: Fixes — General
-
Default list for available bar sizes lists non-standard bars.
[NCR54] (Fixed 31 March 2006; released in AdcData.dll 30.1.1.0)
-
ADC fails to delete non-standard concrete materials.
[NCR55] (Fixed 09 June 2006; released in Adc.exe 8.1.1.0)
-
ADC crashes when run as 'Guest' user.
[NCR57] (Fixed 06 July 2006; released on 6 July 2006 by revised 'eurocode2.ndp' file)
[ top ]
ADC 8.1 Build 1: Fixes — AdBeam
-
ADC redistributes moments at junctions where it gives permissible redistribution as zero.
[NCR52] (Fixed 17 February 2006; released in AdBeam.dll 8.1.0.0)
-
The cover warning message in AbBeam is based on the Bar limits table 'maximum' bar size specified even if this exceeds the 'maximum available' bar size.
[NCR53] (Fixed 31 March 2006; released in AdBeam.dll 8.1.0.0)
[ top ]
ADC 8.1 Build 1: Fixes — AdCol
-
AdCol may crash when opening the Output View to display input data.
[NCR56] (Fixed 4 July 2006; released in Adc.exe 8.1.2.0)
-
For EC2 analysis, the calculated design moment may not give the highest M/Mu value.
[NCR58] (Fixed 24 August 2006; released in AdCol.dll 8.1.1.0)
[ top ]
ADC 8.0 Build 6: New Features
[ top ]
ADC 8.0 Build 6: Fixes
ADC 8.0 Build 6: Fixes — General
-
Selecting the Wizard option via the context menu in some tables fails to open the Wizard.
[NCR23] (Fixed 19 April 2005; released in Adc.exe 8.0.6.0)
-
Output is printed in condensed form only.
[NCR24] (Fixed 17 May 2005; released in Adc.exe 8.0.6.0)
-
ADC 8.0 offers the design code option of "Hong Kong Code of Practice 2004". In fact what
is selected by this option is what was previously labelled "BS8110 (Hong Kong)" and is
"Hong Code Code of Practice 1987".
[NCR39] (Fixed 6 September 2005)
-
ADC may crash upon opening files by double-clicking the filename via 'File | Open' or the
'Recent Files' list if the file has a long filename or is held in a deep folder structure.
This bug is avoided if the file is opened instead by selecting it via a single-click, and
then clicking the 'Open' button.
[NCR41] (Fixed 3 November 2005; released in Adc.exe 8.0.6.0)
-
ADC's 'About Dialog' fails to list all of the program's components.
[NCR42] (Fixed 4 November 2005; released in Adc.exe 8.0.6.0)
-
Formatting scientific values to n significant figures may produce errors (e.g. 8.99999 to
4 sig figs gives 8.100 rather than 9.000).
[NCR45] (Fixed 10 November 2005; released in OaUtil.dll 3.0.15.1)
-
AdCol files, containing large numbers of sections, may take a long time to save after performing
section validation. This is particularly evident when saving over a network. (Part 1 of 2 -
see NCR 48 for Part 2).
[NCR47] (Fixed 28 November 2005; released in AdFile.dll 8.0.4.1)
-
AdCol files may take a long time to save. This is
particularly evident when saving over a network. (Part 2 of 2 - see NCR 47 for Part 1).
[NCR48] (Fixed 28 November 2005)
[ top ]
ADC 8.0 Build 6: Fixes — AdBeam
-
AdBeam crashes when a user load factor is deleted from the input data.
[NCR17] (Fixed 4 April 2005; released in AdcData.dll 8.0.5)
-
AdBeam may fail to present the full list of warnings/errors upon attempting a design,
though the design results are unavailable - indicating that design has not been
performed.
[NCR19] (Fixed 8 April 2005; released in AdBeam.dll 8.0.5.0)
-
The setting to include beam self weight is saved when set in the General Specification
dialog, but not when set in the Load Details page of the New Model Wizard.
[NCR25] (Fixed 12 May 2005; released in Adc.exe 8.0.5.0 and AdcData.dll 8.0.6.0)
-
When designing a solid slab AdBeam invites the user to enter a side cover unnecessarily.
[NCR18] (Fixed 17 May 2005; released in Adc.exe 8.0.6.0)
-
ADC does not check correctly whether the maximum shear in a beam exceeds the BS8110 limit
of 0.8 x √fcu or 5N/mm2. It checks the shear at a distance 'd'
from supports rather that at the supports.
[NCR26] (Fixed 6 May 2005; released in AdBeam.dll 8.0.6.0)
-
The online help incorrectly suggests that the user has control over whether 'd' should
be used when determining the position of the shear check.
[NCR27] (Fixed 31 May 2005)
-
Designs that contained bunched bars in ADC 7.2 may fail to be achieved in ADC 8.0. The
warning 'Error in beam design' may be shown.
[NCR29] (Fixed 7 June 2005; released in AdBeam.dll 8.0.5.0)
-
AdBeam may fail to analyse a model, or may even crash, due to unitialised materials. This problem
occurs when the Section Wizard is used in the 'span and support details' page of the New Model
Wizard to enter upper or lower column sections. To avoid the problem either (a) enter the
section descriptions directly without clicking the 'Section' button (but instead by typing e.g.
'STD R 300 300') or (b) upon completion of the New Model Wizard, initialise the
materials by opening the materials dialog from the program's gateway, and clicking 'OK'.
[NCR31] (Fixed 24 June 2005; released in Adc.exe 8.0.5.0)
-
The 'Notional Loads' table view shows a column 'Direction'. This is not necessary, since the
sign of the load indicates its direction.
[NCR34] (Fixed 24 June 2005; released in Adc.exe 8.0.6.0)
-
It should be possible to click the 'standard' or 'user-defined' title in the gateway and have
the already opened table view change the active tab. This does is not functioning correctly
for the 'Load Factors' and 'Load Combinations' tables.
[NCR35] (Fixed 24 June 2005; released in Adc.exe 8.0.6.0)
-
AdBeam may give misleading solutions for a beam that is unreinforceable e.g. it may suggest a
solution of T16 bars when the maximum bar size is limited to 50 mm, but appear to fail to
find the same solution when the maximum bar size is 80 mm. AdBeam has in fact failed to
recognise that the section was unreinforceable in both cases.
[NCR37] (Fixed 14 July 2005; released in AdBeam.dll 8.0.6.0)
-
AdBeam may recommend solutions whose longitudinal reinforcement in tension is spaced at more
than the maximum allowed by the design code or the reinforcement detailing manual.
[NCR38] (Fixed 8 August 2005; released in AdBeam.dll 8.0.6.0)
-
The Loads table in the Output View shows the values of the loads but not their positions. The values
are mis-aligned with their column headers.
[NCR40] (Fixed 13 September 2005; released in Adc.exe 8.0.6.0)
-
The Wizard button should be disabled for the Redistribution table if redistribution results are
available, and for the Covers table if design results are available.
[NCR43] (Fixed 9 November 2005)
-
AdBeam may crash when designing a flat slab or ribbed slab after installing the patch version 8.0.6.0
of AdBeam.dll.
[NCR44] (Fixed 10 November 2005; released in AdRib.dll 8.0.5.0 and AdSlab.dll 8.0.5.0)
[ top ]
ADC 8.0 Build 6: Fixes — AdCol
-
If the required cover is not a multiple of 5 mm, then AdCol should round it up
to the nearest 5 mm. However, in some circumstances AdCol may add 5 mm to the cover
unnecessarily if the minimum cover is 40 mm or more.
[NCR20] (Fixed 17 May 2005; released in AdBeam.dll 8.0.5.1)
-
If the user switches from biaxial bending to uniaxial bending in AdCol, then Mzz moments
should be disabled and ignored. This adjustment may not always be made, so design moments
may show a moment about the z axis, and axial force/moment charts may show a moment angle
not equal to 0 degrees.
[NCR21] (Fixed 17 May 2005; released in Adc.exe 8.0.5.0 and AdcData.dll 8.0.6.0)
-
AdCol gives incorrent results when a user defined reinforcement or concrete materials
are used.
[NCR36] (Fixed 7 July 2005; released in Adc.exe 8.0.5.0)
-
ADC corrects the sign of column moment results incorrectly when reading and writing via AdExport
during automated testing. This affects comparisons of test results only, and not results
that are evident to the user via the program's interface.
[NCR46] (Fixed 10 November 2005; released in AdExport.dll 8.0.5.0)
[ top ]
ADC 8.0 Build 5: New Features
[ top ]
ADC 8.0 Build 5: Fixes
ADC 8.0 Build 5: Fixes — AdBeam
-
AdBeam crashes when a user load factor is deleted from the input data.
[NCR17] (Fixed 4 April 2005; released in AdcData.dll 8.0.5)
[ top ]
ADC 8.0 Build 4: New Features
ADC 8.0 Build 4: New Features — AdCol
-
AdCol results are now shown diagrammatically on the graphical view, and textually in its legend.
An analysis case 'selector' droplist has been added to the graphical view to facilitate the
the selection of an analysis case for which results are to be shown.
-
Intermediate results that are used in deriving design moments for AdCol are now shown
in the Output View.
[ top ]
ADC 8.0 Build 4: Fixes
ADC 8.0 Build 4: Fixes — AdBeam
-
The Output View fails to display the load factors for combinations in the Prescribed
Load Combinations and User Load Combinations tables.
[NCR12] (Fixed 9 December 2004)
-
Program help contains a beam design example whose diagram, text and input data
are inconsistent.
[NCR13] (Fixed 11 December 2004)
-
The user-specified factor to be applied to the area of reinforcement is applied
incorrectly to the bottom, mid-span reinforcement always, rather than to all tension
reinforcement. It is also applied to areas of shear links. This bug-fix removes
this factor altogether.
[NCR14] (Fixed 16 February 2005)
-
ADC may propose a design that has longitudinal bar sizes that are
smaller than the user-specified minimum.
[NCR15] (Fixed 16 February 2005)
[ top ]
ADC 8.0 Build 1: New Features
ADC 8.0 Build 1: New Features — AdCol
AdCol has been implemented. Its features are:
- Concrete column analysis and design
- Reinforcement detailing checks according to BS8110, Hong Kong Code of Practice and Eurocode 2
- Adjustment of moments for additional/2nd order and eccentricity/imperfection effects according to BS8110,
Hong Kong Code of Practice and Eurocode 2
- Rectangular, circular and hollow circular sections
- Reinforcement and concrete materials consistent with BS8110, Hong Kong Code of Practice and Eurocode 2 standard grades
- Printing of input data, section diagrams and results
- Calculation and display of:
- force-moment interaction graphs
- Mx/My moment interaction graphs
- Export to AdSec.
[ top ]
ADC 8.0 Build 1: Fixes
ADC 8.0 Build 1: Fixes — General
-
ADC crashes when trying to create an output view for
a model with notional loads.
[NCR 1]
-
The design stage may give inconsistent bar sizes in spans over and immediately
either side of columns.
[NCR 2]
-
The area of reinforcement required at the ends of slabs
that are supported by beams may be calculated incorrectly using a lever
arm based on the depth of the supporting beam. The effective depth at these points
may be reported incorrectly.
[NCR5]
-
Span/Effective Depth calculations may give incorrect results when hogging
moments produce a greater requirement for tension reinforcement than do sagging
moments at the relevant position of the beam or slab.
[NCR6]
-
The reported value of Basic Span/Effective Depth Ratio for cantilevered beams with
non-rectangular sections may be incorrect.
[NCR8]
-
When a data file that contains a beam with a General I Section is opened
the width of the bottom flange is set to the width of the top
flange.
[NCR9]
-
Structures with final spans supported by both (a) an upper column whose end condition
is encastre and (b) a lower column whose end condition is pinned, may be analysed
incorrectly as pinned at both ends.
[NCR10]
-
AdSlab reloads the default bar spacings when a data file is opened, thus adding these
to any spacings previously set by the user.
[NCR11]
[ top ]
ADC Outstanding Bugs
ADC Outstanding Bugs — AdBeam
-
Output of effective depth and its value used in calculations is misleading when the
bar size of the solution is not the size of the largest bar allowed by the user.
[NCR 7 now NCR 1343]
[ top ]